Framing is the work behind the work. Every kitchen, bathroom, basement, and addition starts with the lumber that defines the space. A framing crew that gets the dimensions, the structural details, and the rough openings right makes everything that follows easier — drywall hangs straight, doors fit, cabinets meet the wall cleanly. A framing crew that doesn’t gets you a project that fights you for the rest of its life. We frame interior partitions, structural walls, basements, additions, and the engineered work that supports renovations on existing homes.
Where framing fits in a renovation
Most homeowners don’t think about framing as a service they hire — they think about the finished space. But every project has a framing phase, and the quality of that phase determines a lot.
Interior partition framing — building new walls inside an existing space. Standard 2×4 stud walls, 16″ on centre, with proper top and bottom plates, headers over openings, blocking for fixtures. Cosmetic but important: a partition wall framed slightly out of plumb means trim that has to be scribed for the rest of the home’s life.
Structural framing — load-bearing walls, beam pockets, floor joists, roof framing. This is where engineering comes in. Replacing a load-bearing wall with an LVL or steel beam to open up a space requires a structural engineer’s calculation and stamp, a permit, and inspection. We don’t take down a load-bearing wall on contractor judgement — every structural change goes through engineering.
Basement framing — over a finished concrete floor or against a foundation wall. Different rules than upstairs work: the bottom plate has to be pressure-treated or isolated from the slab; the wall has to allow for some foundation movement; insulation and vapour management need to integrate with the framing.
Addition framing — second-storey additions, rear extensions, dormers, garage conversions. This is the heaviest framing work we do, with the most engineering and inspection involvement. A rear addition has to tie into the existing structure properly: rim joists, rafters, roof tie-ins, foundation connection at the new wall lines.
Engineered lumber and modern framing
The trade has changed. Modern residential framing in the GTA increasingly uses engineered lumber where dimension lumber used to be standard:
- LVL (Laminated Veneer Lumber) — beams that span longer distances than dimension lumber can. Replacing a load-bearing wall typically uses an LVL beam sized to the span and load.
- I-joists (TJI, BCI) — engineered floor joists, dimensionally stable, longer spans. Common in newer GTA construction.
- LSL and PSL columns — engineered columns where dimension lumber can’t carry the point load.
- Steel beams and posts — for spans or loads beyond what wood handles.
The choice between dimension lumber and engineered product is driven by span, load, and code requirements — not contractor preference. We work with the structural engineer to specify what each project actually needs.
What it costs in 2026
Honest ranges for GTA framing work:
- Single interior partition wall (8 ft long, 8 ft tall) — $400 to $900 framed (no drywall), depending on whether plumbing or electrical needs to be accommodated.
- Load-bearing wall removal with LVL beam — $4,500 to $12,000 including engineering, beam, supports, and the framing modifications around the opening.
- Basement framing (1,000 sq. ft.) — $6,000 to $11,000 for the framing alone (insulation, drywall, finishes are separate).
- Rear addition framing (300–500 sq. ft. single-storey) — $25,000 to $55,000 framed and weather-tight (foundation, exterior sheathing, roof framing, windows roughed in). Finishes are separate.
- Second-storey addition framing — $80,000 to $200,000+ framed and weather-tight.
The structural work is where unexpected costs hide. A wall that looked like a partition turns out to be load-bearing once we open the ceiling. The existing floor joists are undersized for the new load. The foundation needs reinforcement at the new bearing point. We do due-diligence before quoting major structural work — opening exploratory holes if needed — to keep change orders to a minimum.
Permits, codes, and engineering
Any structural change requires a building permit. The permit application requires drawings — typically architectural drawings for the layout and structural drawings (or notes from a structural engineer) for the load-carrying elements. Drawings are stamped by a licensed engineer or architect for anything beyond simple partition work.
The Ontario Building Code requirements that come up in framing: minimum stud sizes for wall heights (2×4 16″ OC handles 9′ walls; taller walls need 2×6 or closer spacing), header requirements over openings (sized to span and load), bracing requirements for tall walls, fire-blocking in concealed spaces, and the structural drawings/calculations for any load-bearing modification.
Inspection visits during framing: structural framing inspection before closing walls, sometimes a separate foundation inspection for additions, sometimes a roof framing inspection for second-storey work. We schedule and attend every inspection.
GTA-specific considerations
Older GTA homes (pre-1980) often have framing that doesn’t match current code. Stud spacing irregular, headers undersized for the openings they span, joists at non-standard sizes. None of that has to be brought up to code unless the renovation touches it — but renovations frequently do touch it.
Brampton and Mississauga’s mid-century housing stock typically has 2×4 walls, 8′ ceilings, and dimension-lumber floor joists. Standard framing applies for any addition or modification.
Burlington and Oakville have a wider range — heritage homes with timber framing in the older neighbourhoods, modern stick framing in the newer subdivisions. Heritage homes need a different approach: working with the existing structure rather than against it, often with engineering involvement on every change.
Niagara Falls’ older housing stock includes balloon framing in some pre-war homes (continuous studs from foundation to roof, no fire-blocking between floors) — modifications to balloon-framed walls often require fire-blocking retrofit during the renovation.
Why homeowners hire us for framing
Carpenters who frame to spec, not to “good enough.” We work with structural engineers on every load-bearing modification. We catch and correct issues with existing framing during the demo phase rather than building over them. Two-year workmanship warranty on framing — though good framing typically lasts the life of the building.
Framing services in your city
Pick your city to see what’s typical for framing there — common housing stock, structural patterns we see often, and recent projects.
Frequently asked questions
How do I know if a wall is load-bearing?
Three rough indicators: it runs perpendicular to the floor joists above; it’s roughly in the centre of the home or aligned with another wall on the floor below; or you can see structural elements (beams, posts) above or below it. The only definitive answer is a structural engineer’s review of the framing — which we arrange when a wall removal is on the table.
Can you frame an addition before I have permits?
No. We don’t start any structural work without permits. We can do design work, engineering coordination, and material orders during the permit phase, but the lumber doesn’t get ordered onto site until the permit is in hand.
How long does framing take in a renovation?
Interior partitions for a basement: 3–5 days. Load-bearing wall removal with beam: 1–2 days plus engineering and permit lead time. Rear addition framing: 2–4 weeks weather-tight. Second-storey addition: 4–8 weeks weather-tight.
What’s the difference between an architect and a structural engineer?
Architect designs the space (layout, look, function); engineer designs the structure (how it holds up). For a basic renovation, sometimes only an engineer is needed (for the structural changes) plus a designer for layout. For additions, you usually want both.
Can I keep the old framing if it’s solid?
Often yes, if it meets code for the new use. Sometimes no, if the renovation increases loads beyond what the existing framing handles. We assess case by case during demo.